Model No.: QM
Production Capacity: 1000 tons / month
Delivery Date: in one week
Usage: Repair expansion joint conc...
Final setting: 35mins
Pulling strength: 2.8Mpa
Open traffic time: 2 hour
Certificate: ISO9001
Means of Transport: Ocean
Packing: 25kg/bag
Brand Name: HUINENG
Initial setting: 25mins
Compressive strength: 33.0Mpa/ 2 hours
Expansion rate: 0.01%
Color: Grey
Inspection report: MSDS

1.Rapid repair,1 hour open to traffic
2.Strong bonding performance
3.High compressive strength
4.Small color difference
5.Good match

       Bridge Expansion Joint Concrete Repair Products


There are many damages on bridge expansion joint concrete, 

such as: cracks, potholes, broken,exposed reinforcing bar etc.


Detailed repair solution:

1: which kind repair material is best for expansion joint concrete broken?

Huineng brand QM type concrete repair material is very suitable for repair expansion joint concrete cracks, potholes,

broken, exposed reinforcing bar,edge failure etc damages. rapid setting, 1 hour open to traffic.

2: why QM type concrete repair material is suitable?

1)1h open to traffic:

Fast with strength,2h compressive strength ≥33Mpa, 2h flexural strength ≥5Mpa,

Fully meet bridge rapid repairing,reduce traffic congestion.

2)Bonding tightly: No break and fall off from normal concrete under heavy load.

3)High strength: Compressive and flexural strength in late period, both reach 2-3 times of normal concrete. Compressive strength:1d≥60Mpa, 28d≥80Mpa,Flexural strength ≥10Mpa.

4)Good toughness:Impact resistance strength is 8-10 times of normal concrete

impact resistance strength

5)No drying cracks in repaired area and original concrete 

6)Good match:Heat expansion and cold contraction coefficient is nearly same with original concrete.

7)Small color difference: Color of repaired area is close to original concrete.

8)Fast repair: 

Just need chisel damage area accurately,produce less waste, high efficiency, road closed time is short.

3: what is the testing data?

Test items 

Unit

Technical requirement

Test result 

Individual conclusion

Setting time

Initial setting

Min

≥20

  25

Meet requirement

Final setting 

≤60

  35

Compressive strength

2h

Mpa

≥20

  33.0

Meet requirement

1d

≥40

  66.1

28d

≥50

  90.5

Flexural strength

2h


     ≥4

  5.5

Meet requirement

1d

     ≥6

  10.5

28d

     ≥8

  13.5

Pulling strength

28d

Mpa

     ≥2.0

   2.8

Meet requirement

Expansion rate

28d

 /

0.00%-0.1%

   0.01%

Meet requirement

4:What is the repair process? Very easy, just 7 steps as below:

Ms. alisa
skype Ms. alisa
saler
Tel: 86-371-65775236
Mobile: 135 2676 8303
Contact to this supplier

Didn't find what you're looking for? Post Buying Lead or contact HiSupplier Customer Service Center  for help!

Related Search

Find more related products in following catalogs on Hisupplier.com

Related Products

Company Info

Henan Huineng Road And Bridge Technology Co.ltd. [China (Mainland)]


Business Type:Manufacturer, Trading Company
City: Zhengzhou
Province/State: Henan
Country/Region: China (Mainland)

alisa:   skype
alisa:   qq

You May Like: